Home > Heat Pump Chillers > Ultra-Efficient Small Chillers

Ultra-Efficient Air Conditioning & Heating & Hot Water
Small Air Cooled Ductless Heat Pump Chillers

chiller heat pump outdoor unit celing mount fan coil unit for chillerlow wall or floor mount chiller fan coil unit
Floor fan coil unit with feet, for chiller heat pump

CX34 2 Tons Cooling/ 3 Tons Heating. Self-contained R410a chiller heat pump.

*IPLV Cooling 24,000 BTU
COP 6.15
EER 21


*NPLV Cooling 29,000 BTU
COP 8.79
EER 30

*Heating COP 3.92
Cap. 33,813 BTU

CX34 Supports up to 8 indoor units per system.

Five sizes of indoor units range from 3,400 BTU to 14,800 BTU for use in ductless or mini-split chiller configuration with no lineset limits. CXI units are universal mount for floor, wall, or ceiling. The CX34 also works with hydronic floor heating, ducted central HVAC design, boilers, and solar. Modular for 2, 4, 6+ ton systems.

FREE WATER HEATING!
Get up to 70% of your annual water heating energy
for free.

CX34 ultra-efficient R410a reverse cycle air cooled chiller w/ DC inverter compressor, DC inverter pump, DC inverter condenser fan, and DC inverter fan coils. MODBUS capable. Patent pending.

For ductless, ducted/central, hydronic floor heating - any or all can be used in combination. Ductless configuration eliminates duct loss and duct installation cost. Stackable to 2 / 4 / 6+ tons. Sealed, self-contained R410a outdoor unit. No lineset limits, low cost installation with no refrigeration license needed.

Save 70% on your annual water heating costs. Let the Chiltrix chiller built-in water heating function be your primary source of hot water and get a savings of 70% or more on water heating costs.


The Chiltrix small air cooled chiller compressor is fully variable in capacity and its operation is continuously adjusted to match the required heating or cooling output, avoiding on/off cycling and wasted energy. When measured on an annual basis, the average energy savings produced by the Chiltrix dynamic capacity system can exceed 40-50%.

Chiltrix uses a variable speed (VSD) pump for the hydronic loop circulation. When full water flow is not needed due to off-peak capacity requirements, the water pump slows down and uses less energy. The variable speed pump and variable speed compressor work in tandem with the system controller using a special algorithm to keep the compressor and pump both working at the optimum speed. The variable speed condenser fan is controlled in a similar manner. This allows all of the consumers of electrical power within the chiller to operate at the lowest power level to meet the current load. Dynamically controlling the water pump speed and compressor speed independently of each other helps us to achieve the highest levels of performance. In addition, Chiltrix offers DC-Inverter indoor fan coil units, further reducing electrical power consumption (along with lower sound levels and longer lifespan).

Working together, the variable speed compressor, variable speed pump, variable speed condenser fan, and variable speed indoor units all operate at the most efficient level of power consumption possible to meet the demand. From 25% to 100%, the system is always exactly the right size for the job. Under varying real-world conditions the CX34 chiller can efficiently operate at the capacity needed and can achieve up to 50% or more in electrical savings each year compared to a standard chiller, heat pump, or air conditioner. See the details of Chiltrix high efficiency chiller heat pump technology.

The Psychrologix™ psychrometric chiller controller dynamically manages humidity and automatically adjusts the parameters of the chiller in real time, for an off-the-charts increase in efficiency (above its already high rating) when dehumidification is not needed. DHC (Dynamic Humidity Control) can automatically lower the indoor unit coil temperatures to quickly remove any humidity increase. When humidity is within acceptable limits, the system will dynamically reconfigure itself to the most efficient possible operating parameters allowing the chiller to run well above its rated efficiency. The Psychrologix™ chiller control option also adds a wide range of programmable and automated features in addition to DHC and can manage up to three chillers. See the Psychrologix™ DHC controller details here. See the detailed chiller controls white paper here.

The Chiltrix air cooled chiller can also connect to a hot water heat exchanger tank and provide domestic hot water, summer or winter. Save up to 70% or more each year on your water heating costs using our high efficiency heat pump to heat your water. Requires a heat exchanger tank (or a solar tank).

See detailed performance information here.

*Efficiency/capacity data is based on factory performance testing at AHRI 550/590 test conditions. Official AHRI ratings pending. Images are representative only. CX34 replaces CX30. Specifications are subject to change without notice.

Extreme Energy Efficiency that Pays for Itself Quickly

Chiller heating and cooling is inherently more efficient, and lower electricity costs are one reason why chillers are used in all large buildings.

But, small chillers have historically been unable to provide a strong ROI due to high equipment costs and unrealized efficiency potential.

Not any more. Meet the Chiltrix modular chiller family where we have chiller systems as small as 2 tons, with a IPLV cooling ~ EER 21 and heating above COP of 3.9. Installed system costs are about the same as for regular heat pump or air conditioning systems.

Save 50% or more on utility costs. And you can save even more when you also use the CX34 for water heating.

This is not your daddy's chiller. See what's different:

Old news: Chillers are only for large systems of 30 tons or more. Chiltrix chillers modules are 2 tons and can be combined for 4, 6, 8 tons etc. And they are variable capacity, so they can run as low as 25% speed at times when that's all that is needed.

Old news: Chillers are expensive to buy. An installed Chiltrix air cooled chiller system costs no more than a standard AC system.

Old news: Chillers only provide cooling, you need a boiler for heat. Chiltrix chillers are reverse cycle chillers (heat pumps) and can provide heat down to -4F (-20C) They can also connect to an existing boiler system and serve as a lower cost primary heat source.

Old news: Chillers cannot quickly switch between heat/cool modes.
The CX34 can switch modes within
10 minutes.

Old news: Chillers require a cooling tower & have maintenance issues. Our chiller is air cooled, it uses no cooling tower, and is a sealed, maintenance free system.

Common Misconception: Chillers consume water. Chiltrix chillers don't consume any water. Water is only used in the distribution loop. Cooling is performed by a R410a compressor.

The CX34 chiller heat pump replaces the prior model CX30 unit.